baseschematic: ..\..\..\..\..\..\4.2_LTC3406B - DVM ADVANCED.sxsch log_file: ..\..\..\..\dvm_advanced.log simulator: simplis screenshot: schematic.png deck: input.deck init: input.deck.init test_argument: Steady-State|Steady-State|Vin Maximum|10% datetimestamp: 4/18/2013 10:59:52 AM status: RUN scalar: Power(SRC)=249.37m scalar: Power(LOAD123)=225.971m scalar: Efficiency=90.6168% feature: DVM LOAD123#pop scalar: Pk2Pk(VLOAD123)=6.1749m spec: Min_VLOAD123=pass,Min. Output1 Voltage (1.50227) is greater than or equal to Min. Output1 Voltage Spec (1.42975) spec: Max_VLOAD123=pass,Max. Output1 Voltage (1.50844) is less than or equal to Max. Output1 Voltage Spec (1.58025) stats: N/A numgraphs: 4 graphid: 2300 graphname: clock#pop sg: simplis_pop66_2300 path: simplis_pop66_2300.sxgph scalar: Min(ISRC)=350.015u scalar: Max(ISRC)=550.21m scalar: Avg(ISRC)=45.3423m scalar: RMS(ISRC)=110.571m scalar: Min(VSRC)=5.49945 scalar: Max(VSRC)=5.5 scalar: Avg(VSRC)=5.49995 scalar: RMS(VSRC)=5.49995 graphid: 2308 graphname: DVM SRC#pop sg: simplis_pop66_2308 path: simplis_pop66_2308.sxgph curve2325:ISRC,008000 curve2312:VSRC,FF0000 png: simplis_pop66_2308.png scalar: Min(SW)=-862.181m scalar: Max(SW)=6.20005 scalar: Avg(SW)=1.52084 scalar: RMS(SW)=2.64572 scalar: Min(ILOUT)=-122.924u scalar: Max(ILOUT)=405.46m scalar: Avg(ILOUT)=150.075m scalar: RMS(ILOUT)=200.812m scalar: Frequency(CLK)=955.68659kHertz scalar: Min(VOUT)=1.50227 scalar: Max(VOUT)=1.50844 scalar: Avg(VOUT)=1.50572 scalar: RMS(VOUT)=1.50572 graphid: 2313 graphname: default#2313#pop sg: simplis_pop66_2313 path: simplis_pop66_2313.sxgph curve2323:SW,008000 curve2327:ILOUT,0000FF curve2331:CLK,008080 curve2317:VOUT,FF0000 png: simplis_pop66_2313.png scalar: Min(ILOAD123)=149.731m scalar: Max(ILOAD123)=150.346m scalar: Avg(ILOAD123)=150.075m scalar: RMS(ILOAD123)=150.075m scalar: Min(VLOAD123)=1.50227 scalar: Max(VLOAD123)=1.50844 scalar: Avg(VLOAD123)=1.50572 scalar: RMS(VLOAD123)=1.50572 graphid: 2318 graphname: DVM LOAD123#pop sg: simplis_pop66_2318 path: simplis_pop66_2318.sxgph curve2329:ILOAD123,008000 curve2322:VLOAD123,FF0000 png: simplis_pop66_2318.png scalar: Efficiency_Max=90.6168% rstatus: PASS