baseschematic: ..\..\..\..\..\..\4.2_LTC3406B - DVM ADVANCED.sxsch log_file: ..\..\..\..\dvm_advanced.log simulator: simplis screenshot: schematic.png deck: input.deck init: input.deck.init test_argument: Steady-State|Steady-State|Vin Maximum|40% datetimestamp: 4/18/2013 11:00:09 AM status: RUN scalar: Power(SRC)=1.1012 scalar: Power(LOAD123)=903.831m scalar: Efficiency=82.0772% feature: DVM LOAD123#pop scalar: Pk2Pk(VLOAD123)=7.55062m spec: Min_VLOAD123=pass,Min. Output1 Voltage (1.50148) is greater than or equal to Min. Output1 Voltage Spec (1.42975) spec: Max_VLOAD123=pass,Max. Output1 Voltage (1.50903) is less than or equal to Max. Output1 Voltage Spec (1.58025) stats: N/A numgraphs: 4 graphid: 2405 graphname: clock#pop sg: simplis_pop69_2405 path: simplis_pop69_2405.sxgph scalar: Min(ISRC)=465.691u scalar: Max(ISRC)=893.103m scalar: Avg(ISRC)=200.241m scalar: RMS(ISRC)=361.582m scalar: Min(VSRC)=5.49911 scalar: Max(VSRC)=5.5 scalar: Avg(VSRC)=5.4998 scalar: RMS(VSRC)=5.4998 graphid: 2413 graphname: DVM SRC#pop sg: simplis_pop69_2413 path: simplis_pop69_2413.sxgph curve2430:ISRC,008000 curve2417:VSRC,FF0000 png: simplis_pop69_2413.png scalar: Min(SW)=-1.05705 scalar: Max(SW)=5.37317 scalar: Avg(SW)=1.56571 scalar: RMS(SW)=3.01924 scalar: Min(ILOUT)=315.771m scalar: Max(ILOUT)=892.636m scalar: Avg(ILOUT)=600.277m scalar: RMS(ILOUT)=622.971m scalar: Frequency(CLK)=955.65551kHertz scalar: Min(VOUT)=1.50148 scalar: Max(VOUT)=1.50903 scalar: Avg(VOUT)=1.50569 scalar: RMS(VOUT)=1.50569 graphid: 2418 graphname: default#2418#pop sg: simplis_pop69_2418 path: simplis_pop69_2418.sxgph curve2428:SW,008000 curve2432:ILOUT,0000FF curve2436:CLK,008080 curve2422:VOUT,FF0000 png: simplis_pop69_2418.png scalar: Min(VLOAD123)=1.50148 scalar: Max(VLOAD123)=1.50903 scalar: Avg(VLOAD123)=1.50569 scalar: RMS(VLOAD123)=1.50569 scalar: Min(ILOAD123)=598.6m scalar: Max(ILOAD123)=601.61m scalar: Avg(ILOAD123)=600.277m scalar: RMS(ILOAD123)=600.278m graphid: 2423 graphname: DVM LOAD123#pop sg: simplis_pop69_2423 path: simplis_pop69_2423.sxgph curve2427:VLOAD123,FF0000 curve2434:ILOAD123,008000 png: simplis_pop69_2423.png scalar: Efficiency_Max=82.0772% rstatus: PASS