Test Details | |
Schematic | 4.2_LTC3406B - DVM ADVANCED.sxsch |
Test | Steady-State|Steady-State|Vin Nominal|100% |
Date / Time | 4/18/2013 10:59:40 AM |
Report Directory | DVM_REPORTS\2013-04-18-10_58_35_AM\Steady-State\Steady-State\Vin Nominal\100% |
Log File | report.txt |
Screenshot | schematic.png |
Status | PASS |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
Efficiency | 66.4059% |
Efficiency_nom | 66.4059% |
Frequency(CLK) | 955.63221kHertz |
Power(LOAD123) | 2.25924 |
Power(SRC) | 3.40217 |
ILOAD123 | AVG 1.50058 MIN 1.49662 MAX 1.5043 RMS 1.50058 |
ILOUT | AVG 1.50058 MIN 1.20736 MAX 1.79602 RMS 1.51018 |
ISRC | AVG 680.642m MIN 423.708u MAX 1.79645 RMS 1.01914 |
SW | AVG 1.65563 MIN -1.41841 MAX 4.51569 RMS 2.98685 |
VLOAD123 | AVG 1.50557 MIN 1.5016 MAX 1.5093 RMS 1.50558 PK2PK 7.70642m |
VOUT | AVG 1.50557 MIN 1.5016 MAX 1.5093 RMS 1.50558 |
VSRC | AVG 4.99932 MIN 4.9982 MAX 5 RMS 4.99932 |
Measured Spec Values | |
Max_VLOAD123 | PASS: Max. Output1 Voltage (1.5093) is less than or equal to Max. Output1 Voltage Spec (1.58025) |
Min_VLOAD123 | PASS: Min. Output1 Voltage (1.5016) is greater than or equal to Min. Output1 Voltage Spec (1.42975) |
LOAD123
VLOAD123
ILOAD123
|
|
SXGPH File | simplis_pop64_2248.sxgph |
SRC
VSRC
ISRC
|
|
SXGPH File | simplis_pop64_2238.sxgph |
default
CLK
ILOUT
SW
VOUT
|
|
SXGPH File | simplis_pop64_2243.sxgph |
Other SXGPH Files | |
clock#pop | simplis_pop64_2230.sxgph |