baseschematic: ..\..\..\..\..\..\4.2_LTC3406B - DVM ADVANCED.sxsch log_file: ..\..\..\..\dvm_advanced.log simulator: simplis screenshot: schematic.png deck: input.deck init: input.deck.init test_argument: Steady-State|Steady-State|Vin Nominal|40% datetimestamp: 4/18/2013 10:59:06 AM status: RUN scalar: Power(SRC)=1.09925 scalar: Power(LOAD123)=903.775m scalar: Efficiency=82.2174% feature: DVM LOAD123#pop scalar: Pk2Pk(VLOAD123)=7.18152m spec: Min_VLOAD123=pass,Min. Output1 Voltage (1.50172) is greater than or equal to Min. Output1 Voltage Spec (1.42975) spec: Max_VLOAD123=pass,Max. Output1 Voltage (1.5089) is less than or equal to Max. Output1 Voltage Spec (1.58025) stats: N/A numgraphs: 4 graphid: 2020 graphname: clock#pop sg: simplis_pop58_2020 path: simplis_pop58_2020.sxgph scalar: Min(VSRC)=4.99912 scalar: Max(VSRC)=5 scalar: Avg(VSRC)=4.99978 scalar: RMS(VSRC)=4.99978 scalar: Min(ISRC)=423.376u scalar: Max(ISRC)=878.027m scalar: Avg(ISRC)=219.879m scalar: RMS(ISRC)=377.485m graphid: 2028 graphname: DVM SRC#pop sg: simplis_pop58_2028 path: simplis_pop58_2028.sxgph curve2032:VSRC,FF0000 curve2045:ISRC,008000 png: simplis_pop58_2028.png scalar: Min(VOUT)=1.50172 scalar: Max(VOUT)=1.5089 scalar: Avg(VOUT)=1.50564 scalar: RMS(VOUT)=1.50564 scalar: Min(SW)=-1.05104 scalar: Max(SW)=4.86791 scalar: Avg(SW)=1.56567 scalar: RMS(SW)=2.86588 scalar: Min(ILOUT)=328.953m scalar: Max(ILOUT)=877.603m scalar: Avg(ILOUT)=600.258m scalar: RMS(ILOUT)=620.824m scalar: Frequency(CLK)=955.65338kHertz graphid: 2033 graphname: default#2033#pop sg: simplis_pop58_2033 path: simplis_pop58_2033.sxgph curve2037:VOUT,FF0000 curve2043:SW,008000 curve2047:ILOUT,0000FF curve2051:CLK,008080 png: simplis_pop58_2033.png scalar: Min(VLOAD123)=1.50172 scalar: Max(VLOAD123)=1.5089 scalar: Avg(VLOAD123)=1.50564 scalar: RMS(VLOAD123)=1.50564 scalar: Min(ILOAD123)=598.695m scalar: Max(ILOAD123)=601.558m scalar: Avg(ILOAD123)=600.258m scalar: RMS(ILOAD123)=600.259m graphid: 2038 graphname: DVM LOAD123#pop sg: simplis_pop58_2038 path: simplis_pop58_2038.sxgph curve2042:VLOAD123,FF0000 curve2049:ILOAD123,008000 png: simplis_pop58_2038.png scalar: Efficiency_nom=82.2174% rstatus: PASS