back to overview ^

» DVM Test Report: Post-Process 2 Scalars

Test Details
Schematic 6.3_LTC3406B - DVM ADVANCED.sxsch
Test Post-Process 2 Scalars
Date / Time 4/30/2013 3:20:58 PM
Report Directory DVM_REPORTS\2013-04-30-3_20_49_PM\Post-Process 2 Scalars
Log File report.txt
Screenshot schematic.png
Status PASS
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
Frequency(CLK) 955.63308kHertz
my_2pi 6.2831853
my_pi 3.1415927
GAIN
MIN
-61.6648
MAX
30.3333
ILOAD
MIN
1.49635
MAX
1.50441
ILOUT
MIN
1.11755
MAX
1.89
ISRC
MIN
466.041u
MAX
1.89047
PHASE
MIN
-168.703
MAX
86.7445
SW
MIN
-1.456
MAX
5.05159
VLOAD
MIN
1.50133
MAX
1.50942
VOUT
MIN
1.50133
MAX
1.50942
VSRC
MIN
5.49811
MAX
5.5
Measured Spec Values
Max_VLOAD PASS: Max. Output1 Voltage (1.50942) is less than or equal to Max. Output1 Voltage Spec (1.58025)
Min_VLOAD PASS: Min. Output1 Voltage (1.50133) is greater than or equal to Min. Output1 Voltage Spec (1.42975)
LOAD
VLOAD
ILOAD
SXGPH File simplis_pop41_1899.sxgph
Bode Plot
GAIN
PHASE
SXGPH File simplis_ac41_1916.sxgph
SRC
VSRC
ISRC
SXGPH File simplis_pop41_1889.sxgph
default
CLK
ILOUT
SW
VOUT
SXGPH File simplis_pop41_1894.sxgph
Other SXGPH Files
DVM Bode Plot Input#log#ac simplis_ac41_1923.sxgph
clock#pop simplis_pop41_1881.sxgph