baseschematic: ..\..\..\..\..\..\LTC3406B - DVM ADVANCED.sxsch log_file: ..\..\..\..\dvm_advanced.log simulator: simplis deck: input.deck init: input.deck.init test_argument: Transient|Short Circuit|Vin Maximum|100% Load to Short Circuit and Recover datetimestamp: 5/23/2011 15:23:35 PM status: RUN scalar: sw_freq=955.639k feature: DVM LOAD1#tran scalar: Min(VLOAD1 in Reg.)=1.50229 scalar: Max(VLOAD1 in Reg.)=1.51138 scalar: Avg(VLOAD1 in Reg.)=1.50724 scalar: RMS(VLOAD1 in Reg.)=1.50724 spec: min_vout1_reg=pass,Min. Output1 Voltage in Reg. (1.50229) is greater than or equal to Min. Output1 Voltage Spec (1.42975) spec: max_vout1_reg=pass,Max. Output1 Voltage in Reg. (1.51138) is less than or equal to Max. Output1 Voltage Spec (1.58025) scalar: vout1_recovery_time=13.5359u spec: max_vout1_overshoot=fail,Max. Overshoot Output1 Voltage (1.62371) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) scalar: Min(ILOAD1 in Reg.)=1.4973 scalar: Max(ILOAD1 in Reg.)=1.50637 scalar: Avg(ILOAD1 in Reg.)=1.50224 scalar: RMS(ILOAD1 in Reg.)=1.50224 stats: N/A numgraphs: 4 graphid: 6973 graphname: DVM LOAD1#tran sg: simplis_tran127_6973 path: simplis_tran127_6973.sxgph curve6977:VLOAD1,FF0000 scalar: Min(VLOAD1)=9.37839m scalar: Max(VLOAD1)=1.62371 curve6980:ILOAD1,008000 scalar: Min(ILOAD1)=9.54948m scalar: Max(ILOAD1)=151.93 png: simplis_tran127_6973.png graphid: 6953 graphname: default#6953#tran sg: simplis_tran127_6953 path: simplis_tran127_6953.sxgph curve6982:FREQUENCY,0000FF scalar: Min(FREQUENCY)=0 scalar: Max(FREQUENCY)=5 png: simplis_tran127_6953.png graphid: 6958 graphname: clock#tran sg: simplis_tran127_6958 path: simplis_tran127_6958.sxgph graphid: 6968 graphname: DVM SRC1#tran sg: simplis_tran127_6968 path: simplis_tran127_6968.sxgph curve6972:VSRC1,FF0000 scalar: Min(VSRC1)=5.49788 scalar: Max(VSRC1)=5.5 curve6978:ISRC1,008000 scalar: Min(ISRC1)=465.724u scalar: Max(ISRC1)=2.12056 png: simplis_tran127_6968.png rstatus: FAIL