back to overview ^

» DVM Test Report: Transient|Startup|50% Load|0V to Vin Nominal

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Startup|50% Load|0V to Vin Nominal
Date / Time 5/23/2011 15:21:13 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Startup\50% Load\0V to Vin Nominal
Log File report.txt
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 955.649k
vout1_turn_on_time 38.7334u
ILOAD1 in Reg.
AVG
750.252m
MIN
748.233m
MAX
751.965m
RMS
750.253m
VLOAD1 in Reg.
AVG
1.5055
MIN
1.50145
MAX
1.50894
RMS
1.50551
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
-498.677n
MAX
848.036m
ISRC1
MIN
-1.98756
MAX
1.79927
VLOAD1
MIN
5.51955n
MAX
1.70172
VSRC1
MIN
1.98756m
MAX
5
Measured Spec Values
max_vout1_overshoot FAIL: Max. Overshoot Output1 Voltage (1.70172) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
min_vout1_reg PASS: Min. Output1 Voltage in Reg. (1.50145) is greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1_reg PASS: Max. Output1 Voltage in Reg. (1.50894) is less than or equal to Max. Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran105_6183.sxgph
SRC1
VSRC1
ISRC1
SXGPH File simplis_tran105_6178.sxgph
default
FREQUENCY
SXGPH File simplis_tran105_6161.sxgph
Other SXGPH Files
clock#tran simplis_tran105_6166.sxgph