| Test Details | |
| Schematic | LTC3406B - DVM ADVANCED.sxsch |
| Test | Transient|Step Load|Vin Maximum|100% Load to 75% Load |
| Date / Time | 5/23/2011 15:19:30 PM |
| Report Directory | DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Maximum\100% Load to 75% Load |
| Log File | report.txt |
| Status | FAIL |
| Simulator | simplis |
| Deck | input.deck |
| Init | input.deck.init |
| Measured Scalar Values | |
| sw_freq | 955.643k |
| vout1_recovery_time | 16.5411u |
| FREQUENCY | MIN 0 MAX 5 |
| ILOAD1 | MIN 1.10452 MAX 1.50451 |
| ISRC1 | MIN 465.531u MAX 1.81961 |
| VLOAD1 | MIN 1.48444 MAX 1.64444 |
| VSRC1 | MIN 5.49818 MAX 5.5 |
| Measured Spec Values | |
| min_vout1 | PASS: Min. Output1 Voltage (1.48444) is greater than or equal to Min. Output1 Voltage Spec (1.42975) |
| max_vout1 | FAIL: Max. Output1 Voltage (1.64444) is not less than or equal to Max. Output1 Voltage Spec (1.58025) |
| max_vout1_overshoot | FAIL: Max. Overshoot Output1 Voltage (1.64444) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
![]() LOAD1
VLOAD1
ILOAD1
|
|
| SXGPH File | simplis_tran86_5499.sxgph |
![]() SRC1
VSRC1
ISRC1
|
|
| SXGPH File | simplis_tran86_5494.sxgph |
![]() default
FREQUENCY
|
|
| SXGPH File | simplis_tran86_5477.sxgph |
| Other SXGPH Files | |
| clock#tran | simplis_tran86_5482.sxgph |