DVM - Design Verification Module
|
The AcSource() function changes the AC voltage and frequency of a AC line source, without changing the subcircuit definition used by the source symbol. This function can only be placed in the Source column.
The AcSource() function changes the AC_VOLTAGE1 and FREQUENCY parameters on the source, no other parameters are changed.
To set the voltage and frequency of a source, use the following syntax:
AcSource(REF, LINE_RANGE, VOLTAGE, FREQUENCY)
Argument | Range | Description |
REF |
n/a |
The actual reference designator of the DVM Source or the more generic syntax of INPUT:n where n is an integer indicating a position in the list of managed DVM sources. |
LINE_RANGE |
LL or HL |
The line range to select the correct symbolic voltage value. This can only be the two strings LL or HL. |
VOLTAGE |
min:0 |
The RMS voltage for the input source. The voltage can be a numeric value or a symbolic value, such as a percentage of nominal input voltage. Symbolic values use the LINE_RANGE parameter to find the correct symbolic value. |
FREQUENCY |
min: > 0 |
The AC line frequency of the input source. This is used to both set the frequency of the input source and to set the simulation timing. The frequency can be a numeric or a symbolic value, such as F_High or F_Low. |