back to overview ^

» DVM Test Report: Transient|Short Circuit|Vin Maximum|50% Load to Short Circuit and Recover

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Short Circuit|Vin Maximum|50% Load to Short Circuit and Recover
Date / Time 5/23/2011 15:23:28 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Short Circuit\Vin Maximum\50% Load to Short Circuit and Recover
Log File report.txt
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 955.681k
vout1_recovery_time 29.7443u
ILOAD1 in Reg.
AVG
758.991m
MIN
753.345m
MAX
764.438m
RMS
758.997m
VLOAD1 in Reg.
AVG
1.52304
MIN
1.51171
MAX
1.53397
RMS
1.52305
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
6.6392m
MAX
151.129
ISRC1
MIN
465.473u
MAX
2.2709
VLOAD1
MIN
9.44234m
MAX
1.97513
VSRC1
MIN
5.49773
MAX
5.5
Measured Spec Values
max_vout1_overshoot FAIL: Max. Overshoot Output1 Voltage (1.97513) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
min_vout1_reg PASS: Min. Output1 Voltage in Reg. (1.51171) is greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1_reg PASS: Max. Output1 Voltage in Reg. (1.53397) is less than or equal to Max. Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran126_6937.sxgph
SRC1
VSRC1
ISRC1
SXGPH File simplis_tran126_6932.sxgph
default
FREQUENCY
SXGPH File simplis_tran126_6917.sxgph
Other SXGPH Files
clock#tran simplis_tran126_6922.sxgph