| General | |
| LTC3406B - DVM ADVANCED.sxsch |
| dvm_advanced.testplan |
| 2011-05-23 15:12:10 PM |
| DVM_REPORTS\2011-05-23-15_12_01_PM |
| dvm_advanced.log |
| 129 of 129 (129 of 129 Run, 67 Passed, 61 Failed, 1 Ran with Warnings, 0 Skipped) |
| 12m 4s |
|
| Design Specifications | |
| LTC3406B |
| Synchronous Buck |
| 5.000 V (4.5 V to 5.5 V) |
| 1.505 V @ 1.500 A (±5%) |
| 955kHz |
|
| Excel-compatible Results | |
| dvm_advanced_table_scalars.txt |
| dvm_advanced_table_specs.txt |
|
| Test 1 of 129 | |
| Ac Analysis|Bode Plot|Vin Nominal|Light Load |
| simplis |
| Ac Analysis\Bode Plot\Vin Nominal\Light Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 2 of 129 | |
| Ac Analysis|Bode Plot|Vin Nominal|50% Load |
| simplis |
| Ac Analysis\Bode Plot\Vin Nominal\50% Load\report.txt.html |
| PASS |
| 5s |
|
| Test 3 of 129 | |
| Ac Analysis|Bode Plot|Vin Nominal|100% Load |
| simplis |
| Ac Analysis\Bode Plot\Vin Nominal\100% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 4 of 129 | |
| Ac Analysis|Bode Plot|Vin Minimum|Light Load |
| simplis |
| Ac Analysis\Bode Plot\Vin Minimum\Light Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 5 of 129 | |
| Ac Analysis|Bode Plot|Vin Minimum|50% Load |
| simplis |
| Ac Analysis\Bode Plot\Vin Minimum\50% Load\report.txt.html |
| PASS |
| 5s |
|
| Test 6 of 129 | |
| Ac Analysis|Bode Plot|Vin Minimum|100% Load |
| simplis |
| Ac Analysis\Bode Plot\Vin Minimum\100% Load\report.txt.html |
| WARN |
| 4s |
|
| Test 7 of 129 | |
| Ac Analysis|Bode Plot|Vin Maximum|Light Load |
| simplis |
| Ac Analysis\Bode Plot\Vin Maximum\Light Load\report.txt.html |
| FAIL |
| 6s |
|
| Test 8 of 129 | |
| Ac Analysis|Bode Plot|Vin Maximum|50% Load |
| simplis |
| Ac Analysis\Bode Plot\Vin Maximum\50% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 9 of 129 | |
| Ac Analysis|Bode Plot|Vin Maximum|100% Load |
| simplis |
| Ac Analysis\Bode Plot\Vin Maximum\100% Load\report.txt.html |
| PASS |
| 5s |
|
| Test 10 of 129 | |
| Ac Analysis|Conducted Susceptibility|Vin Nominal|Light Load |
| simplis |
| Ac Analysis\Conducted Susceptibility\Vin Nominal\Light Load\report.txt.html |
| PASS |
| 3s |
|
| Test 11 of 129 | |
| Ac Analysis|Conducted Susceptibility|Vin Nominal|50% Load |
| simplis |
| Ac Analysis\Conducted Susceptibility\Vin Nominal\50% Load\report.txt.html |
| PASS |
| 3s |
|
| Test 12 of 129 | |
| Ac Analysis|Conducted Susceptibility|Vin Nominal|100% Load |
| simplis |
| Ac Analysis\Conducted Susceptibility\Vin Nominal\100% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 13 of 129 | |
| Ac Analysis|Conducted Susceptibility|Vin Minimum|Light Load |
| simplis |
| Ac Analysis\Conducted Susceptibility\Vin Minimum\Light Load\report.txt.html |
| PASS |
| 4s |
|
| Test 14 of 129 | |
| Ac Analysis|Conducted Susceptibility|Vin Minimum|50% Load |
| simplis |
| Ac Analysis\Conducted Susceptibility\Vin Minimum\50% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 15 of 129 | |
| Ac Analysis|Conducted Susceptibility|Vin Minimum|100% Load |
| simplis |
| Ac Analysis\Conducted Susceptibility\Vin Minimum\100% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 16 of 129 | |
| Ac Analysis|Conducted Susceptibility|Vin Maximum|Light Load |
| simplis |
| Ac Analysis\Conducted Susceptibility\Vin Maximum\Light Load\report.txt.html |
| PASS |
| 3s |
|
| Test 17 of 129 | |
| Ac Analysis|Conducted Susceptibility|Vin Maximum|50% Load |
| simplis |
| Ac Analysis\Conducted Susceptibility\Vin Maximum\50% Load\report.txt.html |
| PASS |
| 3s |
|
| Test 18 of 129 | |
| Ac Analysis|Conducted Susceptibility|Vin Maximum|100% Load |
| simplis |
| Ac Analysis\Conducted Susceptibility\Vin Maximum\100% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 19 of 129 | |
| Ac Analysis|Input Impedance|Vin Nominal|Light Load |
| simplis |
| Ac Analysis\Input Impedance\Vin Nominal\Light Load\report.txt.html |
| PASS |
| 3s |
|
| Test 20 of 129 | |
| Ac Analysis|Input Impedance|Vin Nominal|50% Load |
| simplis |
| Ac Analysis\Input Impedance\Vin Nominal\50% Load\report.txt.html |
| PASS |
| 3s |
|
| Test 21 of 129 | |
| Ac Analysis|Input Impedance|Vin Nominal|100% Load |
| simplis |
| Ac Analysis\Input Impedance\Vin Nominal\100% Load\report.txt.html |
| PASS |
| 3s |
|
| Test 22 of 129 | |
| Ac Analysis|Input Impedance|Vin Minimum|Light Load |
| simplis |
| Ac Analysis\Input Impedance\Vin Minimum\Light Load\report.txt.html |
| PASS |
| 4s |
|
| Test 23 of 129 | |
| Ac Analysis|Input Impedance|Vin Minimum|50% Load |
| simplis |
| Ac Analysis\Input Impedance\Vin Minimum\50% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 24 of 129 | |
| Ac Analysis|Input Impedance|Vin Minimum|100% Load |
| simplis |
| Ac Analysis\Input Impedance\Vin Minimum\100% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 25 of 129 | |
| Ac Analysis|Input Impedance|Vin Maximum|Light Load |
| simplis |
| Ac Analysis\Input Impedance\Vin Maximum\Light Load\report.txt.html |
| PASS |
| 4s |
|
| Test 26 of 129 | |
| Ac Analysis|Input Impedance|Vin Maximum|50% Load |
| simplis |
| Ac Analysis\Input Impedance\Vin Maximum\50% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 27 of 129 | |
| Ac Analysis|Input Impedance|Vin Maximum|100% Load |
| simplis |
| Ac Analysis\Input Impedance\Vin Maximum\100% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 28 of 129 | |
| Ac Analysis|Output Impedance|Vin Nominal|Light Load |
| simplis |
| Ac Analysis\Output Impedance\Vin Nominal\Light Load\report.txt.html |
| PASS |
| 4s |
|
| Test 29 of 129 | |
| Ac Analysis|Output Impedance|Vin Nominal|50% Load |
| simplis |
| Ac Analysis\Output Impedance\Vin Nominal\50% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 30 of 129 | |
| Ac Analysis|Output Impedance|Vin Nominal|100% Load |
| simplis |
| Ac Analysis\Output Impedance\Vin Nominal\100% Load\report.txt.html |
| PASS |
| 3s |
|
| Test 31 of 129 | |
| Ac Analysis|Output Impedance|Vin Minimum|Light Load |
| simplis |
| Ac Analysis\Output Impedance\Vin Minimum\Light Load\report.txt.html |
| PASS |
| 3s |
|
| Test 32 of 129 | |
| Ac Analysis|Output Impedance|Vin Minimum|50% Load |
| simplis |
| Ac Analysis\Output Impedance\Vin Minimum\50% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 33 of 129 | |
| Ac Analysis|Output Impedance|Vin Minimum|100% Load |
| simplis |
| Ac Analysis\Output Impedance\Vin Minimum\100% Load\report.txt.html |
| PASS |
| 3s |
|
| Test 34 of 129 | |
| Ac Analysis|Output Impedance|Vin Maximum|Light Load |
| simplis |
| Ac Analysis\Output Impedance\Vin Maximum\Light Load\report.txt.html |
| PASS |
| 4s |
|
| Test 35 of 129 | |
| Ac Analysis|Output Impedance|Vin Maximum|50% Load |
| simplis |
| Ac Analysis\Output Impedance\Vin Maximum\50% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 36 of 129 | |
| Ac Analysis|Output Impedance|Vin Maximum|100% Load |
| simplis |
| Ac Analysis\Output Impedance\Vin Maximum\100% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 37 of 129 | |
| Transient|Step Load|Vin Nominal|Light Load to 25% Load |
| simplis |
| Transient\Step Load\Vin Nominal\Light Load to 25% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 38 of 129 | |
| Transient|Step Load|Vin Nominal|Light Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Nominal\Light Load to 50% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 39 of 129 | |
| Transient|Step Load|Vin Nominal|Light Load to 100% Load |
| simplis |
| Transient\Step Load\Vin Nominal\Light Load to 100% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 40 of 129 | |
| Transient|Step Load|Vin Nominal|25% Load to Light Load |
| simplis |
| Transient\Step Load\Vin Nominal\25% Load to Light Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 41 of 129 | |
| Transient|Step Load|Vin Nominal|25% Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Nominal\25% Load to 50% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 42 of 129 | |
| Transient|Step Load|Vin Nominal|50% Load to Light Load |
| simplis |
| Transient\Step Load\Vin Nominal\50% Load to Light Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 43 of 129 | |
| Transient|Step Load|Vin Nominal|50% Load to 25% Load |
| simplis |
| Transient\Step Load\Vin Nominal\50% Load to 25% Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 44 of 129 | |
| Transient|Step Load|Vin Nominal|50% Load to 75% Load |
| simplis |
| Transient\Step Load\Vin Nominal\50% Load to 75% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 45 of 129 | |
| Transient|Step Load|Vin Nominal|50% Load to 100% Load |
| simplis |
| Transient\Step Load\Vin Nominal\50% Load to 100% Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 46 of 129 | |
| Transient|Step Load|Vin Nominal|75% Load to 100% Load |
| simplis |
| Transient\Step Load\Vin Nominal\75% Load to 100% Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 47 of 129 | |
| Transient|Step Load|Vin Nominal|75% Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Nominal\75% Load to 50% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 48 of 129 | |
| Transient|Step Load|Vin Nominal|100% Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Nominal\100% Load to 50% Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 49 of 129 | |
| Transient|Step Load|Vin Nominal|100% Load to 75% Load |
| simplis |
| Transient\Step Load\Vin Nominal\100% Load to 75% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 50 of 129 | |
| Transient|Step Load|Vin Nominal|100% Load to Light Load |
| simplis |
| Transient\Step Load\Vin Nominal\100% Load to Light Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 51 of 129 | |
| Transient|Step Load|Vin Nominal|100% Load to No Load |
| simplis |
| Transient\Step Load\Vin Nominal\100% Load to No Load\report.txt.html |
| FAIL |
| 6s |
|
| Test 52 of 129 | |
| Transient|Step Load|Vin Minimum|Light Load to 25% Load |
| simplis |
| Transient\Step Load\Vin Minimum\Light Load to 25% Load\report.txt.html |
| FAIL |
| 6s |
|
| Test 53 of 129 | |
| Transient|Step Load|Vin Minimum|Light Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Minimum\Light Load to 50% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 54 of 129 | |
| Transient|Step Load|Vin Minimum|Light Load to 100% Load |
| simplis |
| Transient\Step Load\Vin Minimum\Light Load to 100% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 55 of 129 | |
| Transient|Step Load|Vin Minimum|25% Load to Light Load |
| simplis |
| Transient\Step Load\Vin Minimum\25% Load to Light Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 56 of 129 | |
| Transient|Step Load|Vin Minimum|25% Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Minimum\25% Load to 50% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 57 of 129 | |
| Transient|Step Load|Vin Minimum|50% Load to Light Load |
| simplis |
| Transient\Step Load\Vin Minimum\50% Load to Light Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 58 of 129 | |
| Transient|Step Load|Vin Minimum|50% Load to 25% Load |
| simplis |
| Transient\Step Load\Vin Minimum\50% Load to 25% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 59 of 129 | |
| Transient|Step Load|Vin Minimum|50% Load to 75% Load |
| simplis |
| Transient\Step Load\Vin Minimum\50% Load to 75% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 60 of 129 | |
| Transient|Step Load|Vin Minimum|50% Load to 100% Load |
| simplis |
| Transient\Step Load\Vin Minimum\50% Load to 100% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 61 of 129 | |
| Transient|Step Load|Vin Minimum|75% Load to 100% Load |
| simplis |
| Transient\Step Load\Vin Minimum\75% Load to 100% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 62 of 129 | |
| Transient|Step Load|Vin Minimum|75% Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Minimum\75% Load to 50% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 63 of 129 | |
| Transient|Step Load|Vin Minimum|100% Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Minimum\100% Load to 50% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 64 of 129 | |
| Transient|Step Load|Vin Minimum|100% Load to 75% Load |
| simplis |
| Transient\Step Load\Vin Minimum\100% Load to 75% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 65 of 129 | |
| Transient|Step Load|Vin Minimum|100% Load to Light Load |
| simplis |
| Transient\Step Load\Vin Minimum\100% Load to Light Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 66 of 129 | |
| Transient|Step Load|Vin Minimum|100% Load to No Load |
| simplis |
| Transient\Step Load\Vin Minimum\100% Load to No Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 67 of 129 | |
| Transient|Step Load|Vin Maximum|Light Load to 25% Load |
| simplis |
| Transient\Step Load\Vin Maximum\Light Load to 25% Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 68 of 129 | |
| Transient|Step Load|Vin Maximum|Light Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Maximum\Light Load to 50% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 69 of 129 | |
| Transient|Step Load|Vin Maximum|Light Load to 100% Load |
| simplis |
| Transient\Step Load\Vin Maximum\Light Load to 100% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 70 of 129 | |
| Transient|Step Load|Vin Maximum|25% Load to Light Load |
| simplis |
| Transient\Step Load\Vin Maximum\25% Load to Light Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 71 of 129 | |
| Transient|Step Load|Vin Maximum|25% Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Maximum\25% Load to 50% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 72 of 129 | |
| Transient|Step Load|Vin Maximum|50% Load to Light Load |
| simplis |
| Transient\Step Load\Vin Maximum\50% Load to Light Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 73 of 129 | |
| Transient|Step Load|Vin Maximum|50% Load to 25% Load |
| simplis |
| Transient\Step Load\Vin Maximum\50% Load to 25% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 74 of 129 | |
| Transient|Step Load|Vin Maximum|50% Load to 75% Load |
| simplis |
| Transient\Step Load\Vin Maximum\50% Load to 75% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 75 of 129 | |
| Transient|Step Load|Vin Maximum|50% Load to 100% Load |
| simplis |
| Transient\Step Load\Vin Maximum\50% Load to 100% Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 76 of 129 | |
| Transient|Step Load|Vin Maximum|75% Load to 100% Load |
| simplis |
| Transient\Step Load\Vin Maximum\75% Load to 100% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 77 of 129 | |
| Transient|Step Load|Vin Maximum|75% Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Maximum\75% Load to 50% Load\report.txt.html |
| FAIL |
| 3s |
|
| Test 78 of 129 | |
| Transient|Step Load|Vin Maximum|100% Load to 50% Load |
| simplis |
| Transient\Step Load\Vin Maximum\100% Load to 50% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 79 of 129 | |
| Transient|Step Load|Vin Maximum|100% Load to 75% Load |
| simplis |
| Transient\Step Load\Vin Maximum\100% Load to 75% Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 80 of 129 | |
| Transient|Step Load|Vin Maximum|100% Load to Light Load |
| simplis |
| Transient\Step Load\Vin Maximum\100% Load to Light Load\report.txt.html |
| FAIL |
| 5s |
|
| Test 81 of 129 | |
| Transient|Step Load|Vin Maximum|100% Load to No Load |
| simplis |
| Transient\Step Load\Vin Maximum\100% Load to No Load\report.txt.html |
| FAIL |
| 4s |
|
| Test 82 of 129 | |
| Transient|Step Line|Light Load|Vin Minimum to Vin Nominal |
| simplis |
| Transient\Step Line\Light Load\Vin Minimum to Vin Nominal\report.txt.html |
| PASS |
| 4s |
|
| Test 83 of 129 | |
| Transient|Step Line|Light Load|Vin Minimum to Vin Maximum |
| simplis |
| Transient\Step Line\Light Load\Vin Minimum to Vin Maximum\report.txt.html |
| PASS |
| 4s |
|
| Test 84 of 129 | |
| Transient|Step Line|Light Load|Vin Maximum to Vin Nominal |
| simplis |
| Transient\Step Line\Light Load\Vin Maximum to Vin Nominal\report.txt.html |
| PASS |
| 4s |
|
| Test 85 of 129 | |
| Transient|Step Line|Light Load|Vin Maximum to Vin Minimum |
| simplis |
| Transient\Step Line\Light Load\Vin Maximum to Vin Minimum\report.txt.html |
| PASS |
| 3s |
|
| Test 86 of 129 | |
| Transient|Step Line|50% Load|Vin Minimum to Vin Nominal |
| simplis |
| Transient\Step Line\50% Load\Vin Minimum to Vin Nominal\report.txt.html |
| PASS |
| 3s |
|
| Test 87 of 129 | |
| Transient|Step Line|50% Load|Vin Minimum to Vin Maximum |
| simplis |
| Transient\Step Line\50% Load\Vin Minimum to Vin Maximum\report.txt.html |
| PASS |
| 4s |
|
| Test 88 of 129 | |
| Transient|Step Line|50% Load|Vin Maximum to Vin Nominal |
| simplis |
| Transient\Step Line\50% Load\Vin Maximum to Vin Nominal\report.txt.html |
| PASS |
| 3s |
|
| Test 89 of 129 | |
| Transient|Step Line|50% Load|Vin Maximum to Vin Minimum |
| simplis |
| Transient\Step Line\50% Load\Vin Maximum to Vin Minimum\report.txt.html |
| PASS |
| 3s |
|
| Test 90 of 129 | |
| Transient|Step Line|100% Load|Vin Minimum to Vin Nominal |
| simplis |
| Transient\Step Line\100% Load\Vin Minimum to Vin Nominal\report.txt.html |
| PASS |
| 4s |
|
| Test 91 of 129 | |
| Transient|Step Line|100% Load|Vin Minimum to Vin Maximum |
| simplis |
| Transient\Step Line\100% Load\Vin Minimum to Vin Maximum\report.txt.html |
| PASS |
| 4s |
|
| Test 92 of 129 | |
| Transient|Step Line|100% Load|Vin Maximum to Vin Nominal |
| simplis |
| Transient\Step Line\100% Load\Vin Maximum to Vin Nominal\report.txt.html |
| PASS |
| 4s |
|
| Test 93 of 129 | |
| Transient|Step Line|100% Load|Vin Maximum to Vin Minimum |
| simplis |
| Transient\Step Line\100% Load\Vin Maximum to Vin Minimum\report.txt.html |
| PASS |
| 4s |
|
| Test 94 of 129 | |
| Transient|Startup|Light Load|0V to Vin Minimum |
| simplis |
| Transient\Startup\Light Load\0V to Vin Minimum\report.txt.html |
| FAIL |
| 6s |
|
| Test 95 of 129 | |
| Transient|Startup|Light Load|0V to Vin Nominal |
| simplis |
| Transient\Startup\Light Load\0V to Vin Nominal\report.txt.html |
| FAIL |
| 6s |
|
| Test 96 of 129 | |
| Transient|Startup|Light Load|0V to Vin Maximum |
| simplis |
| Transient\Startup\Light Load\0V to Vin Maximum\report.txt.html |
| FAIL |
| 5s |
|
| Test 97 of 129 | |
| Transient|Startup|50% Load|0V to Vin Minimum |
| simplis |
| Transient\Startup\50% Load\0V to Vin Minimum\report.txt.html |
| FAIL |
| 4s |
|
| Test 98 of 129 | |
| Transient|Startup|50% Load|0V to Vin Nominal |
| simplis |
| Transient\Startup\50% Load\0V to Vin Nominal\report.txt.html |
| FAIL |
| 4s |
|
| Test 99 of 129 | |
| Transient|Startup|50% Load|0V to Vin Maximum |
| simplis |
| Transient\Startup\50% Load\0V to Vin Maximum\report.txt.html |
| FAIL |
| 5s |
|
| Test 100 of 129 | |
| Transient|Startup|100% Load|0V to Vin Minimum |
| simplis |
| Transient\Startup\100% Load\0V to Vin Minimum\report.txt.html |
| PASS |
| 4s |
|
| Test 101 of 129 | |
| Transient|Startup|100% Load|0V to Vin Nominal |
| simplis |
| Transient\Startup\100% Load\0V to Vin Nominal\report.txt.html |
| PASS |
| 4s |
|
| Test 102 of 129 | |
| Transient|Startup|100% Load|0V to Vin Maximum |
| simplis |
| Transient\Startup\100% Load\0V to Vin Maximum\report.txt.html |
| PASS |
| 4s |
|
| Test 103 of 129 | |
| Transient|Short Circuit|Vin Nominal|Light Load to Short Circuit |
| simplis |
| Transient\Short Circuit\Vin Nominal\Light Load to Short Circuit\report.txt.html |
| PASS |
| 4s |
|
| Test 104 of 129 | |
| Transient|Short Circuit|Vin Nominal|50% Load to Short Circuit |
| simplis |
| Transient\Short Circuit\Vin Nominal\50% Load to Short Circuit\report.txt.html |
| PASS |
| 3s |
|
| Test 105 of 129 | |
| Transient|Short Circuit|Vin Nominal|100% Load to Short Circuit |
| simplis |
| Transient\Short Circuit\Vin Nominal\100% Load to Short Circuit\report.txt.html |
| PASS |
| 4s |
|
| Test 106 of 129 | |
| Transient|Short Circuit|Vin Minimum|Light Load to Short Circuit |
| simplis |
| Transient\Short Circuit\Vin Minimum\Light Load to Short Circuit\report.txt.html |
| PASS |
| 4s |
|
| Test 107 of 129 | |
| Transient|Short Circuit|Vin Minimum|50% Load to Short Circuit |
| simplis |
| Transient\Short Circuit\Vin Minimum\50% Load to Short Circuit\report.txt.html |
| PASS |
| 7s |
|
| Test 108 of 129 | |
| Transient|Short Circuit|Vin Minimum|100% Load to Short Circuit |
| simplis |
| Transient\Short Circuit\Vin Minimum\100% Load to Short Circuit\report.txt.html |
| PASS |
| 3s |
|
| Test 109 of 129 | |
| Transient|Short Circuit|Vin Maximum|Light Load to Short Circuit |
| simplis |
| Transient\Short Circuit\Vin Maximum\Light Load to Short Circuit\report.txt.html |
| PASS |
| 4s |
|
| Test 110 of 129 | |
| Transient|Short Circuit|Vin Maximum|50% Load to Short Circuit |
| simplis |
| Transient\Short Circuit\Vin Maximum\50% Load to Short Circuit\report.txt.html |
| PASS |
| 3s |
|
| Test 111 of 129 | |
| Transient|Short Circuit|Vin Maximum|100% Load to Short Circuit |
| simplis |
| Transient\Short Circuit\Vin Maximum\100% Load to Short Circuit\report.txt.html |
| PASS |
| 3s |
|
| Test 112 of 129 | |
| Transient|Short Circuit|Vin Nominal|Light Load to Short Circuit and Recover |
| simplis |
| Transient\Short Circuit\Vin Nominal\Light Load to Short Circuit and Recover\report.txt.html |
| FAIL |
| 5s |
|
| Test 113 of 129 | |
| Transient|Short Circuit|Vin Nominal|50% Load to Short Circuit and Recover |
| simplis |
| Transient\Short Circuit\Vin Nominal\50% Load to Short Circuit and Recover\report.txt.html |
| FAIL |
| 6s |
|
| Test 114 of 129 | |
| Transient|Short Circuit|Vin Nominal|100% Load to Short Circuit and Recover |
| simplis |
| Transient\Short Circuit\Vin Nominal\100% Load to Short Circuit and Recover\report.txt.html |
| PASS |
| 5s |
|
| Test 115 of 129 | |
| Transient|Short Circuit|Vin Minimum|Light Load to Short Circuit and Recover |
| simplis |
| Transient\Short Circuit\Vin Minimum\Light Load to Short Circuit and Recover\report.txt.html |
| FAIL |
| 5s |
|
| Test 116 of 129 | |
| Transient|Short Circuit|Vin Minimum|50% Load to Short Circuit and Recover |
| simplis |
| Transient\Short Circuit\Vin Minimum\50% Load to Short Circuit and Recover\report.txt.html |
| FAIL |
| 5s |
|
| Test 117 of 129 | |
| Transient|Short Circuit|Vin Minimum|100% Load to Short Circuit and Recover |
| simplis |
| Transient\Short Circuit\Vin Minimum\100% Load to Short Circuit and Recover\report.txt.html |
| PASS |
| 5s |
|
| Test 118 of 129 | |
| Transient|Short Circuit|Vin Maximum|Light Load to Short Circuit and Recover |
| simplis |
| Transient\Short Circuit\Vin Maximum\Light Load to Short Circuit and Recover\report.txt.html |
| FAIL |
| 6s |
|
| Test 119 of 129 | |
| Transient|Short Circuit|Vin Maximum|50% Load to Short Circuit and Recover |
| simplis |
| Transient\Short Circuit\Vin Maximum\50% Load to Short Circuit and Recover\report.txt.html |
| FAIL |
| 6s |
|
| Test 120 of 129 | |
| Transient|Short Circuit|Vin Maximum|100% Load to Short Circuit and Recover |
| simplis |
| Transient\Short Circuit\Vin Maximum\100% Load to Short Circuit and Recover\report.txt.html |
| FAIL |
| 4s |
|
| Test 121 of 129 | |
| Steady-State|Steady-State|Vin Nominal|Light Load |
| simplis |
| Steady-State\Steady-State\Vin Nominal\Light Load\report.txt.html |
| PASS |
| 3s |
|
| Test 122 of 129 | |
| Steady-State|Steady-State|Vin Nominal|50% Load |
| simplis |
| Steady-State\Steady-State\Vin Nominal\50% Load\report.txt.html |
| PASS |
| 3s |
|
| Test 123 of 129 | |
| Steady-State|Steady-State|Vin Nominal|100% Load |
| simplis |
| Steady-State\Steady-State\Vin Nominal\100% Load\report.txt.html |
| PASS |
| 4s |
|
| Test 124 of 129 | |
| Steady-State|Steady-State|Vin Minimum|Light Load |
| simplis |
| Steady-State\Steady-State\Vin Minimum\Light Load\report.txt.html |
| PASS |
| 3s |
|
| Test 125 of 129 | |
| Steady-State|Steady-State|Vin Minimum|50% Load |
| simplis |
| Steady-State\Steady-State\Vin Minimum\50% Load\report.txt.html |
| PASS |
| 3s |
|
| Test 126 of 129 | |
| Steady-State|Steady-State|Vin Minimum|100% Load |
| simplis |
| Steady-State\Steady-State\Vin Minimum\100% Load\report.txt.html |
| PASS |
| 3s |
|
| Test 127 of 129 | |
| Steady-State|Steady-State|Vin Maximum|Light Load |
| simplis |
| Steady-State\Steady-State\Vin Maximum\Light Load\report.txt.html |
| PASS |
| 3s |
|
| Test 128 of 129 | |
| Steady-State|Steady-State|Vin Maximum|50% Load |
| simplis |
| Steady-State\Steady-State\Vin Maximum\50% Load\report.txt.html |
| PASS |
| 2s |
|
| Test 129 of 129 | |
| Steady-State|Steady-State|Vin Maximum|100% Load |
| simplis |
| Steady-State\Steady-State\Vin Maximum\100% Load\report.txt.html |
| PASS |
| 3s |