back to overview ^

» DVM Test Report: Transient|Short Circuit|Vin Minimum|100% Load to Short Circuit and Recover

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Short Circuit|Vin Minimum|100% Load to Short Circuit and Recover
Date / Time 5/23/2011 15:23:11 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Short Circuit\Vin Minimum\100% Load to Short Circuit and Recover
Log File report.txt
Status PASS
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 928.382k
vout1_recovery_time 31.8019u
ILOAD1 in Reg.
AVG
1.44254
MIN
1.43812
MAX
1.44675
RMS
1.44254
VLOAD1 in Reg.
AVG
1.44734
MIN
1.44291
MAX
1.45157
RMS
1.44734
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
15.2013m
MAX
146.691
ISRC1
MIN
381.224u
MAX
1.72054
VLOAD1
MIN
7.49893m
MAX
1.45349
VSRC1
MIN
4.49828
MAX
4.5
Measured Spec Values
max_vout1_overshoot PASS: Max. Overshoot Output1 Voltage (1.45157) is less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
min_vout1_reg PASS: Min. Output1 Voltage in Reg. (1.44291) is greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1_reg PASS: Max. Output1 Voltage in Reg. (1.45157) is less than or equal to Max. Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran124_6865.sxgph
SRC1
ISRC1
VSRC1
SXGPH File simplis_tran124_6860.sxgph
default
FREQUENCY
SXGPH File simplis_tran124_6845.sxgph
Other SXGPH Files
clock#tran simplis_tran124_6850.sxgph