back to overview ^

» DVM Test Report: Transient|Short Circuit|Vin Minimum|50% Load to Short Circuit and Recover

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Short Circuit|Vin Minimum|50% Load to Short Circuit and Recover
Date / Time 5/23/2011 15:23:03 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Short Circuit\Vin Minimum\50% Load to Short Circuit and Recover
Log File report.txt
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 955.696k
vout1_recovery_time 30.0377u
ILOAD1 in Reg.
AVG
760.048m
MIN
756.146m
MAX
763.573m
RMS
760.05m
VLOAD1 in Reg.
AVG
1.52516
MIN
1.51733
MAX
1.53223
RMS
1.52516
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
4.48732m
MAX
151.209
ISRC1
MIN
380.843u
MAX
1.83016
VLOAD1
MIN
7.55971m
MAX
1.82178
VSRC1
MIN
4.49817
MAX
4.5
Measured Spec Values
max_vout1_overshoot FAIL: Max. Overshoot Output1 Voltage (1.82178) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
min_vout1_reg PASS: Min. Output1 Voltage in Reg. (1.51733) is greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1_reg PASS: Max. Output1 Voltage in Reg. (1.53223) is less than or equal to Max. Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran123_6829.sxgph
SRC1
VSRC1
ISRC1
SXGPH File simplis_tran123_6824.sxgph
default
FREQUENCY
SXGPH File simplis_tran123_6809.sxgph
Other SXGPH Files
clock#tran simplis_tran123_6814.sxgph