back to overview ^

» DVM Test Report: Transient|Short Circuit|Vin Nominal|50% Load to Short Circuit and Recover

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Short Circuit|Vin Nominal|50% Load to Short Circuit and Recover
Date / Time 5/23/2011 15:22:41 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Short Circuit\Vin Nominal\50% Load to Short Circuit and Recover
Log File report.txt
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 955.681k
vout1_recovery_time 29.7157u
ILOAD1 in Reg.
AVG
758.412m
MIN
753.431m
MAX
763.216m
RMS
758.416m
VLOAD1 in Reg.
AVG
1.52188
MIN
1.51188
MAX
1.53152
RMS
1.52189
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
8.89507m
MAX
151.167
ISRC1
MIN
423.157u
MAX
2.09885
VLOAD1
MIN
8.46744m
MAX
1.8987
VSRC1
MIN
4.9979
MAX
5
Measured Spec Values
max_vout1_overshoot FAIL: Max. Overshoot Output1 Voltage (1.8987) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
min_vout1_reg PASS: Min. Output1 Voltage in Reg. (1.51188) is greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1_reg PASS: Max. Output1 Voltage in Reg. (1.53152) is less than or equal to Max. Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran120_6721.sxgph
SRC1
VSRC1
ISRC1
SXGPH File simplis_tran120_6716.sxgph
default
FREQUENCY
SXGPH File simplis_tran120_6701.sxgph
Other SXGPH Files
clock#tran simplis_tran120_6706.sxgph