Test Details | |
Schematic | LTC3406B - DVM ADVANCED.sxsch |
Test | Transient|Startup|100% Load|0V to Vin Nominal |
Date / Time | 5/23/2011 15:21:30 PM |
Report Directory | DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Startup\100% Load\0V to Vin Nominal |
Log File | report.txt |
Status | PASS |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
sw_freq | 955.632k |
vout1_turn_on_time | 30.7432u |
ILOAD1 in Reg. | AVG 1.50058 MIN 1.49662 MAX 1.5043 RMS 1.50058 |
VLOAD1 in Reg. | AVG 1.50558 MIN 1.5016 MAX 1.5093 RMS 1.50558 |
FREQUENCY | MIN 0 MAX 5 |
ILOAD1 | MIN -499.122n MAX 1.52811 |
ISRC1 | MIN -1.98756 MAX 1.92045 |
VLOAD1 | MIN 1.65629n MAX 1.5332 |
VSRC1 | MIN 1.98756m MAX 5 |
Measured Spec Values | |
max_vout1_overshoot | PASS: Max. Overshoot Output1 Voltage (1.5332) is less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
min_vout1_reg | PASS: Min. Output1 Voltage in Reg. (1.5016) is greater than or equal to Min. Output1 Voltage Spec (1.42975) |
max_vout1_reg | PASS: Max. Output1 Voltage in Reg. (1.5093) is less than or equal to Max. Output1 Voltage Spec (1.58025) |
LOAD1
VLOAD1
ILOAD1
|
|
SXGPH File | simplis_tran108_6291.sxgph |
SRC1
VSRC1
ISRC1
|
|
SXGPH File | simplis_tran108_6286.sxgph |
default
FREQUENCY
|
|
SXGPH File | simplis_tran108_6269.sxgph |
Other SXGPH Files | |
clock#tran | simplis_tran108_6274.sxgph |