back to overview ^

» DVM Test Report: Transient|Startup|50% Load|0V to Vin Minimum

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Startup|50% Load|0V to Vin Minimum
Date / Time 5/23/2011 15:21:08 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Startup\50% Load\0V to Vin Minimum
Log File report.txt
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 955.649k
vout1_turn_on_time 38.8619u
ILOAD1 in Reg.
AVG
750.235m
MIN
748.396m
MAX
751.884m
RMS
750.236m
VLOAD1 in Reg.
AVG
1.50547
MIN
1.50178
MAX
1.50878
RMS
1.50547
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
-498.677n
MAX
845.628m
ISRC1
MIN
-1.98756
MAX
1.72044
VLOAD1
MIN
5.51955n
MAX
1.69689
VSRC1
MIN
1.98756m
MAX
4.5
Measured Spec Values
max_vout1_overshoot FAIL: Max. Overshoot Output1 Voltage (1.69689) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
min_vout1_reg PASS: Min. Output1 Voltage in Reg. (1.50178) is greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1_reg PASS: Max. Output1 Voltage in Reg. (1.50878) is less than or equal to Max. Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran104_6147.sxgph
SRC1
VSRC1
ISRC1
SXGPH File simplis_tran104_6142.sxgph
default
FREQUENCY
SXGPH File simplis_tran104_6125.sxgph
Other SXGPH Files
clock#tran simplis_tran104_6130.sxgph