back to overview ^

» DVM Test Report: Transient|Step Load|Vin Maximum|50% Load to 100% Load

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Step Load|Vin Maximum|50% Load to 100% Load
Date / Time 5/23/2011 15:19:09 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Maximum\50% Load to 100% Load
Log File report.txt
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 955.502k
vout1_recovery_time 36.3205u
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
748.216m
MAX
1.5467
ISRC1
MIN
465.747u
MAX
2.05699
VLOAD1
MIN
1.18056
MAX
1.59871
VSRC1
MIN
5.49794
MAX
5.5
Measured Spec Values
min_vout1 FAIL: Min. Output1 Voltage (1.18056) is not greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1 FAIL: Max. Output1 Voltage (1.59871) is not less than or equal to Max. Output1 Voltage Spec (1.58025)
max_vout1_overshoot FAIL: Max. Overshoot Output1 Voltage (1.59871) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran82_5353.sxgph
SRC1
ISRC1
VSRC1
SXGPH File simplis_tran82_5348.sxgph
default
FREQUENCY
SXGPH File simplis_tran82_5333.sxgph
Other SXGPH Files
clock#tran simplis_tran82_5338.sxgph