Test Details | |
Schematic | LTC3406B - DVM ADVANCED.sxsch |
Test | Transient|Step Load|Vin Maximum|50% Load to 100% Load |
Date / Time | 5/23/2011 15:19:09 PM |
Report Directory | DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Maximum\50% Load to 100% Load |
Log File | report.txt |
Status | FAIL |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
sw_freq | 955.502k |
vout1_recovery_time | 36.3205u |
FREQUENCY | MIN 0 MAX 5 |
ILOAD1 | MIN 748.216m MAX 1.5467 |
ISRC1 | MIN 465.747u MAX 2.05699 |
VLOAD1 | MIN 1.18056 MAX 1.59871 |
VSRC1 | MIN 5.49794 MAX 5.5 |
Measured Spec Values | |
min_vout1 | FAIL: Min. Output1 Voltage (1.18056) is not greater than or equal to Min. Output1 Voltage Spec (1.42975) |
max_vout1 | FAIL: Max. Output1 Voltage (1.59871) is not less than or equal to Max. Output1 Voltage Spec (1.58025) |
max_vout1_overshoot | FAIL: Max. Overshoot Output1 Voltage (1.59871) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
LOAD1
VLOAD1
ILOAD1
|
|
SXGPH File | simplis_tran82_5353.sxgph |
SRC1
ISRC1
VSRC1
|
|
SXGPH File | simplis_tran82_5348.sxgph |
default
FREQUENCY
|
|
SXGPH File | simplis_tran82_5333.sxgph |
Other SXGPH Files | |
clock#tran | simplis_tran82_5338.sxgph |