Test Details | |
Schematic | LTC3406B - DVM ADVANCED.sxsch |
Test | Transient|Step Load|Vin Maximum|50% Load to 75% Load |
Date / Time | 5/23/2011 15:19:03 PM |
Report Directory | DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Maximum\50% Load to 75% Load |
Log File | report.txt |
Status | FAIL |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
sw_freq | 955.589k |
vout1_recovery_time | 17.2139u |
FREQUENCY | MIN 0 MAX 5 |
ILOAD1 | MIN 748.216m MAX 1.14914 |
ISRC1 | MIN 465.747u MAX 1.55441 |
VLOAD1 | MIN 1.34098 MAX 1.55343 |
VSRC1 | MIN 5.49845 MAX 5.5 |
Measured Spec Values | |
min_vout1 | FAIL: Min. Output1 Voltage (1.34098) is not greater than or equal to Min. Output1 Voltage Spec (1.42975) |
max_vout1 | PASS: Max. Output1 Voltage (1.55343) is less than or equal to Max. Output1 Voltage Spec (1.58025) |
max_vout1_overshoot | PASS: Max. Overshoot Output1 Voltage (1.55343) is less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
LOAD1
VLOAD1
ILOAD1
|
|
SXGPH File | simplis_tran81_5319.sxgph |
SRC1
VSRC1
ISRC1
|
|
SXGPH File | simplis_tran81_5314.sxgph |
default
FREQUENCY
|
|
SXGPH File | simplis_tran81_5297.sxgph |
Other SXGPH Files | |
clock#tran | simplis_tran81_5302.sxgph |