back to overview ^

» DVM Test Report: Transient|Step Load|Vin Minimum|100% Load to 50% Load

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Step Load|Vin Minimum|100% Load to 50% Load
Date / Time 5/23/2011 15:17:59 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Minimum\100% Load to 50% Load
Log File report.txt
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 955.648k
vout1_recovery_time 20.2614u
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
699.089m
MAX
1.44867
ISRC1
MIN
380.848u
MAX
1.72039
VLOAD1
MIN
1.4461
MAX
1.76405
VSRC1
MIN
4.49828
MAX
4.5
Measured Spec Values
min_vout1 PASS: Min. Output1 Voltage (1.4461) is greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1 FAIL: Max. Output1 Voltage (1.76405) is not less than or equal to Max. Output1 Voltage Spec (1.58025)
max_vout1_overshoot FAIL: Max. Overshoot Output1 Voltage (1.76405) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran70_4921.sxgph
SRC1
VSRC1
ISRC1
SXGPH File simplis_tran70_4916.sxgph
default
FREQUENCY
SXGPH File simplis_tran70_4901.sxgph
Other SXGPH Files
clock#tran simplis_tran70_4906.sxgph