| Test Details | |
| Schematic | LTC3406B - DVM ADVANCED.sxsch |
| Test | Transient|Step Load|Vin Minimum|50% Load to 100% Load |
| Date / Time | 5/23/2011 15:17:44 PM |
| Report Directory | DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Minimum\50% Load to 100% Load |
| Log File | report.txt |
| Status | FAIL |
| Simulator | simplis |
| Deck | input.deck |
| Init | input.deck.init |
| Measured Scalar Values | |
| sw_freq | 874.008k |
| vout1_recovery_time | -1 |
| FREQUENCY | MIN 0 MAX 5 |
| ILOAD1 | MIN 748.501m MAX 1.49763 |
| ISRC1 | MIN 381.114u MAX 1.72041 |
| VLOAD1 | MIN 1.18251 MAX 1.5088 |
| VSRC1 | MIN 4.49828 MAX 4.5 |
| Measured Spec Values | |
| min_vout1 | FAIL: Min. Output1 Voltage (1.18251) is not greater than or equal to Min. Output1 Voltage Spec (1.42975) |
| max_vout1 | PASS: Max. Output1 Voltage (1.5088) is less than or equal to Max. Output1 Voltage Spec (1.58025) |
| max_vout1_overshoot | PASS: Max. Overshoot Output1 Voltage (1.50458) is less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
![]() LOAD1
VLOAD1
ILOAD1
|
|
| SXGPH File | simplis_tran67_4815.sxgph |
![]() SRC1
VSRC1
ISRC1
|
|
| SXGPH File | simplis_tran67_4810.sxgph |
![]() default
FREQUENCY
|
|
| SXGPH File | simplis_tran67_4793.sxgph |
| Other SXGPH Files | |
| clock#tran | simplis_tran67_4798.sxgph |