back to overview ^

» DVM Test Report: Transient|Step Load|Vin Minimum|50% Load to 100% Load

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Step Load|Vin Minimum|50% Load to 100% Load
Date / Time 5/23/2011 15:17:44 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Minimum\50% Load to 100% Load
Log File report.txt
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 874.008k
vout1_recovery_time -1
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
748.501m
MAX
1.49763
ISRC1
MIN
381.114u
MAX
1.72041
VLOAD1
MIN
1.18251
MAX
1.5088
VSRC1
MIN
4.49828
MAX
4.5
Measured Spec Values
min_vout1 FAIL: Min. Output1 Voltage (1.18251) is not greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1 PASS: Max. Output1 Voltage (1.5088) is less than or equal to Max. Output1 Voltage Spec (1.58025)
max_vout1_overshoot PASS: Max. Overshoot Output1 Voltage (1.50458) is less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran67_4815.sxgph
SRC1
VSRC1
ISRC1
SXGPH File simplis_tran67_4810.sxgph
default
FREQUENCY
SXGPH File simplis_tran67_4793.sxgph
Other SXGPH Files
clock#tran simplis_tran67_4798.sxgph