Test Details | |
Schematic | LTC3406B - DVM ADVANCED.sxsch |
Test | Transient|Step Load|Vin Minimum|50% Load to 25% Load |
Date / Time | 5/23/2011 15:17:34 PM |
Report Directory | DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Minimum\50% Load to 25% Load |
Log File | report.txt |
Status | FAIL |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
sw_freq | 955.692k |
vout1_recovery_time | 17.4662u |
FREQUENCY | MIN 0 MAX 5 |
ILOAD1 | MIN 351.615m MAX 751.897m |
ISRC1 | MIN 380.833u MAX 1.01266 |
VLOAD1 | MIN 1.45807 MAX 1.66802 |
VSRC1 | MIN 4.49899 MAX 4.5 |
Measured Spec Values | |
min_vout1 | PASS: Min. Output1 Voltage (1.45807) is greater than or equal to Min. Output1 Voltage Spec (1.42975) |
max_vout1 | FAIL: Max. Output1 Voltage (1.66802) is not less than or equal to Max. Output1 Voltage Spec (1.58025) |
max_vout1_overshoot | FAIL: Max. Overshoot Output1 Voltage (1.66802) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
LOAD1
ILOAD1
VLOAD1
|
|
SXGPH File | simplis_tran65_4741.sxgph |
SRC1
VSRC1
ISRC1
|
|
SXGPH File | simplis_tran65_4736.sxgph |
default
FREQUENCY
|
|
SXGPH File | simplis_tran65_4721.sxgph |
Other SXGPH Files | |
clock#tran | simplis_tran65_4726.sxgph |