Test Details | |
Schematic | LTC3406B - DVM ADVANCED.sxsch |
Test | Transient|Step Load|Vin Minimum|75% Load to 100% Load |
Date / Time | 5/23/2011 15:17:49 PM |
Report Directory | DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Minimum\75% Load to 100% Load |
Log File | report.txt |
Status | FAIL |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
sw_freq | 916.455k |
vout1_recovery_time | -1 |
FREQUENCY | MIN 0 MAX 5 |
ILOAD1 | MIN 1.12275 MAX 1.49874 |
ISRC1 | MIN 381.252u MAX 1.72039 |
VLOAD1 | MIN 1.356 MAX 1.50894 |
VSRC1 | MIN 4.49828 MAX 4.5 |
Measured Spec Values | |
min_vout1 | FAIL: Min. Output1 Voltage (1.356) is not greater than or equal to Min. Output1 Voltage Spec (1.42975) |
max_vout1 | PASS: Max. Output1 Voltage (1.50894) is less than or equal to Max. Output1 Voltage Spec (1.58025) |
max_vout1_overshoot | PASS: Max. Overshoot Output1 Voltage (1.50479) is less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
LOAD1
VLOAD1
ILOAD1
|
|
SXGPH File | simplis_tran68_4851.sxgph |
SRC1
VSRC1
ISRC1
|
|
SXGPH File | simplis_tran68_4846.sxgph |
default
FREQUENCY
|
|
SXGPH File | simplis_tran68_4829.sxgph |
Other SXGPH Files | |
clock#tran | simplis_tran68_4834.sxgph |