Test Details | |
Schematic | LTC3406B - DVM ADVANCED.sxsch |
Test | Transient|Step Load|Vin Nominal|100% Load to No Load |
Date / Time | 5/23/2011 15:16:48 PM |
Report Directory | DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Nominal\100% Load to No Load |
Log File | report.txt |
Status | FAIL |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
sw_freq | 955.706k |
vout1_recovery_time | 32.4025u |
FREQUENCY | MIN 0 MAX 5 |
ILOAD1 | MIN 8.10169m MAX 1.5043 |
ISRC1 | MIN 273.936u MAX 1.79645 |
VLOAD1 | MIN 1.5016 MAX 2.04846 |
VSRC1 | MIN 4.9982 MAX 5 |
Measured Spec Values | |
min_vout1 | PASS: Min. Output1 Voltage (1.5016) is greater than or equal to Min. Output1 Voltage Spec (1.42975) |
max_vout1 | FAIL: Max. Output1 Voltage (2.04846) is not less than or equal to Max. Output1 Voltage Spec (1.58025) |
max_vout1_overshoot | FAIL: Max. Overshoot Output1 Voltage (2.04846) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
LOAD1
VLOAD1
ILOAD1
|
|
SXGPH File | simplis_tran58_4489.sxgph |
SRC1
VSRC1
ISRC1
|
|
SXGPH File | simplis_tran58_4484.sxgph |
default
FREQUENCY
|
|
SXGPH File | simplis_tran58_4469.sxgph |
Other SXGPH Files | |
clock#tran | simplis_tran58_4474.sxgph |