back to overview ^

» DVM Test Report: Transient|Step Load|Vin Nominal|25% Load to Light Load

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Step Load|Vin Nominal|25% Load to Light Load
Date / Time 5/23/2011 15:15:38 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Nominal\25% Load to Light Load
Log File report.txt
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 955.546k
vout1_recovery_time 25.618u
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
41.8533m
MAX
375.942m
ISRC1
MIN
300.993u
MAX
645.299m
VLOAD1
MIN
1.47229
MAX
1.66755
VSRC1
MIN
4.99935
MAX
5
Measured Spec Values
min_vout1 PASS: Min. Output1 Voltage (1.47229) is greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1 FAIL: Max. Output1 Voltage (1.66755) is not less than or equal to Max. Output1 Voltage Spec (1.58025)
max_vout1_overshoot FAIL: Max. Overshoot Output1 Voltage (1.66755) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran47_4093.sxgph
SRC1
VSRC1
ISRC1
SXGPH File simplis_tran47_4088.sxgph
default
FREQUENCY
SXGPH File simplis_tran47_4073.sxgph
Other SXGPH Files
clock#tran simplis_tran47_4078.sxgph