| Test Details | |
| Schematic | LTC3406B - DVM ADVANCED.sxsch |
| Test | Transient|Step Load|Vin Nominal|50% Load to 25% Load |
| Date / Time | 5/23/2011 15:15:57 PM |
| Report Directory | DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Nominal\50% Load to 25% Load |
| Log File | report.txt |
| Status | FAIL |
| Simulator | simplis |
| Deck | input.deck |
| Init | input.deck.init |
| Measured Scalar Values | |
| sw_freq | 955.69k |
| vout1_recovery_time | 17.5245u |
| FREQUENCY | MIN 0 MAX 5 |
| ILOAD1 | MIN 351.763m MAX 751.985m |
| ISRC1 | MIN 309.549u MAX 1.03248 |
| VLOAD1 | MIN 1.45837 MAX 1.66858 |
| VSRC1 | MIN 4.99897 MAX 5 |
| Measured Spec Values | |
| min_vout1 | PASS: Min. Output1 Voltage (1.45837) is greater than or equal to Min. Output1 Voltage Spec (1.42975) |
| max_vout1 | FAIL: Max. Output1 Voltage (1.66858) is not less than or equal to Max. Output1 Voltage Spec (1.58025) |
| max_vout1_overshoot | FAIL: Max. Overshoot Output1 Voltage (1.66858) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
![]() LOAD1
VLOAD1
ILOAD1
|
|
| SXGPH File | simplis_tran50_4201.sxgph |
![]() SRC1
VSRC1
ISRC1
|
|
| SXGPH File | simplis_tran50_4196.sxgph |
![]() default
FREQUENCY
|
|
| SXGPH File | simplis_tran50_4181.sxgph |
| Other SXGPH Files | |
| clock#tran | simplis_tran50_4186.sxgph |