Test Details | |
Schematic | LTC3406B - DVM ADVANCED.sxsch |
Test | Transient|Step Load|Vin Nominal|Light Load to 100% Load |
Date / Time | 5/23/2011 15:15:31 PM |
Report Directory | DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Step Load\Vin Nominal\Light Load to 100% Load |
Log File | report.txt |
Status | FAIL |
Simulator | simplis |
Deck | input.deck |
Init | input.deck.init |
Measured Scalar Values | |
sw_freq | 707.059k |
vout1_recovery_time | -1 |
FREQUENCY | MIN 0 MAX 5 |
ILOAD1 | MIN 49.9695m MAX 1.49966 |
ISRC1 | MIN 313.482u MAX 1.92046 |
VLOAD1 | MIN 717.178m MAX 1.50717 |
VSRC1 | MIN 4.99808 MAX 5 |
Measured Spec Values | |
min_vout1 | FAIL: Min. Output1 Voltage (717.178m) is not greater than or equal to Min. Output1 Voltage Spec (1.42975) |
max_vout1 | PASS: Max. Output1 Voltage (1.50717) is less than or equal to Max. Output1 Voltage Spec (1.58025) |
max_vout1_overshoot | PASS: Max. Overshoot Output1 Voltage (1.50403) is less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025) |
LOAD1
VLOAD1
ILOAD1
|
|
SXGPH File | simplis_tran46_4059.sxgph |
SRC1
VSRC1
ISRC1
|
|
SXGPH File | simplis_tran46_4054.sxgph |
default
FREQUENCY
|
|
SXGPH File | simplis_tran46_4037.sxgph |
Other SXGPH Files | |
clock#tran | simplis_tran46_4042.sxgph |