back to overview ^

» DVM Test Report: Transient|Short Circuit|Vin Maximum|100% Load to Short Circuit and Recover

Test Details
Schematic LTC3406B - DVM ADVANCED.sxsch
Test Transient|Short Circuit|Vin Maximum|100% Load to Short Circuit and Recover
Date / Time 5/23/2011 15:23:35 PM
Report Directory DVM_REPORTS\2011-05-23-15_12_01_PM\Transient\Short Circuit\Vin Maximum\100% Load to Short Circuit and Recover
Log File report.txt
Status FAIL
Simulator simplis
Deck input.deck
Init input.deck.init
Measured Scalar Values
sw_freq 955.639k
vout1_recovery_time 13.5359u
ILOAD1 in Reg.
AVG
1.50224
MIN
1.4973
MAX
1.50637
RMS
1.50224
VLOAD1 in Reg.
AVG
1.50724
MIN
1.50229
MAX
1.51138
RMS
1.50724
FREQUENCY
MIN
0
MAX
5
ILOAD1
MIN
9.54948m
MAX
151.93
ISRC1
MIN
465.724u
MAX
2.12056
VLOAD1
MIN
9.37839m
MAX
1.62371
VSRC1
MIN
5.49788
MAX
5.5
Measured Spec Values
max_vout1_overshoot FAIL: Max. Overshoot Output1 Voltage (1.62371) is not less than or equal to Max. Overshoot Output1 Voltage Spec (1.58025)
min_vout1_reg PASS: Min. Output1 Voltage in Reg. (1.50229) is greater than or equal to Min. Output1 Voltage Spec (1.42975)
max_vout1_reg PASS: Max. Output1 Voltage in Reg. (1.51138) is less than or equal to Max. Output1 Voltage Spec (1.58025)
LOAD1
VLOAD1
ILOAD1
SXGPH File simplis_tran127_6973.sxgph
SRC1
VSRC1
ISRC1
SXGPH File simplis_tran127_6968.sxgph
default
FREQUENCY
SXGPH File simplis_tran127_6953.sxgph
Other SXGPH Files
clock#tran simplis_tran127_6958.sxgph